Relay coordination, protection settings and fault analysis that make sure faults are cleared quickly and selectively, keeping people safe and the rest of your network running.
Poorly coordinated protection either trips too much, shutting down healthy parts of the plant, or too little, letting faults damage equipment and endanger people. Most settings are never revisited after the system has changed.
DCPS performs complete protection studies based on short circuit results and equipment data. We calculate settings for overcurrent, earth fault, differential, distance and generator protection, verify CT performance and build time-current coordination curves that prove selectivity across the network.
Settings are issued in a format ready to load into the relays, and our engineers can test and implement them on site.
From individual settings to complete protection philosophy for new and existing networks.
Time-current coordination studies proving selective tripping across the protection chain.
Settings for ANSI 50/51, 87, 21, 27/59, 81 and generator protection functions.
Short circuit studies for all relevant fault types and operating scenarios.
Verification of instrument transformer ratios, burdens and saturation performance.
Protection schemes and philosophy documents for substations, plants and grid connections.
Analysis of relay events and disturbance records to find the root cause of trips.
SLDs, relay types, CT/VT data and existing settings collected.
Short circuit levels calculated for all operating cases.
Relay settings calculated and coordination curves prepared.
Results reviewed with your engineers and refined.
Settings loaded and verified with secondary injection testing.
Complete records that make future changes and audits easy.
After any significant network change such as new transformers, generators, solar plants or a change in grid fault level, and periodically as good practice.
Yes. We calculate settings for the relays already installed and highlight any device that cannot achieve the required performance.
Yes, we can implement settings and verify them through secondary injection testing.
This is usually a coordination problem. A protection study identifies where selectivity is lost and how to correct it.
Power system simulation and analysis using ETAP to improve reliability, performance and operational planning.
Learn MoreComprehensive power system studies using PowerFactory for accurate modelling, analysis and optimization.
Learn MorePower system analysis using PSS®E to evaluate grid performance, stability and system reliability.
Learn MoreSend us your SLD and relay list for a protection study proposal. Call +92 345 2270942 or email info@dcpspak.com.
DCPS PAK
Typically replies within minutes
Any questions related to Services?
WhatsApp Us
🟢 Online | Privacy policy
WhatsApp us