Overhead transmission and distribution line design in PLS-CADD, covering route profiling, structure spotting, sag-tension and clearance checks for safe, cost-effective lines.
Overhead line costs are driven by the number and type of structures, while safety depends on correct clearances in every weather condition. Small design errors become expensive once towers are on the ground.
DCPS uses PLS-CADD to build a 3D model of the line route from survey or LiDAR data, then optimizes structure locations and heights, calculates sag and tension for every span and verifies clearances to ground, crossings and vegetation. Structure capacity checks are carried out with PLS-TOWER and PLS-POLE where required.
The result is an optimized, compliant design with drawings and schedules ready for construction.
Design and analysis services for transmission and distribution line projects.
Survey and LiDAR data processed into an accurate 3D terrain and feature model.
Manual and automatic optimization of structure locations, types and heights along the route.
Conductor and shield wire sag and tension for every span under all design weather cases.
Checks to ground, roads, rivers, buildings, vegetation and crossings with other lines.
Load trees and structure capacity checks using PLS-TOWER and PLS-POLE.
Assessment of existing lines for higher ampacity, new conductors or increased clearances.
Survey, LiDAR, conductor data and design criteria are compiled.
Terrain, criteria, weather cases and structure families are configured.
Structures are spotted and sag-tension calculated for every span.
Clearances and structure loads are checked and the design optimized.
Plan & profile drawings, stringing charts and material schedules.
Everything your contractor needs to build the line correctly.
A route survey or LiDAR data, conductor and hardware details, structure types and the applicable design criteria and weather loads.
Yes. We model existing lines from survey or LiDAR to check clearances, assess uprating potential or plan reconductoring.
We apply the client or utility specification along with standards such as IEC 60826 or NESC, as required by the project.
Yes, stringing charts are provided for each section so contractors can install conductors at the correct tension.
Power system analysis using PSS®E to evaluate grid performance, stability and system reliability.
Learn MoreProtection studies that enhance system safety, fault management and reliable operation of electrical networks.
Learn MorePower system simulation and analysis using ETAP to improve reliability, performance and operational planning.
Learn MoreShare your route and design criteria and we will scope the PLS-CADD work. Call +92 345 2270942 or email info@dcpspak.com.
DCPS PAK
Typically replies within minutes
Any questions related to Services?
WhatsApp Us
🟢 Online | Privacy policy
WhatsApp us