Power Continuity

UPS Systems

Online UPS solutions, battery systems and maintenance that keep your critical loads running cleanly through outages, load-shedding, voltage dips and generator changeover.

UPS Systems

Loads we protect

  • Data centres and server rooms
  • Process control and PLC systems
  • Hospitals and laboratory equipment
  • Banks, telecom and security systems
Overview

Clean, continuous power for critical loads

In Pakistan, power interruptions, voltage fluctuations and generator switching are part of daily operations. For critical equipment, even a few milliseconds of disturbance can mean lost data, damaged electronics or a stopped production line.

DCPS supplies, installs and maintains online double-conversion UPS systems from single-phase units for offices to three-phase modular systems for data centres and industrial plants. We start with a load study, so the UPS is correctly sized for today with headroom for growth, and we design the battery bank around the backup time you actually need.

Our service does not end at installation. Preventive maintenance, battery health checks and fast fault response keep your UPS ready for the moment it matters.

Why DCPS

Correct sizingLoad study, growth margin and redundancy planning
Online topologyDouble-conversion for zero transfer time
Battery expertiseVRLA and lithium-ion bank design and testing
AMC supportPreventive maintenance and emergency response
What We Offer

Complete UPS solutions

Design, supply, installation and lifecycle support for single and three-phase UPS systems.

Load Assessment & Sizing

Measurement of actual load, power factor and harmonics to size the UPS and battery correctly.

Online & Modular UPS

Single and three-phase online double-conversion and modular UPS from small offices to data centres.

Redundant Configurations

N+1 and parallel redundant systems with static bypass for maximum availability of critical loads.

Battery Banks

Battery bank design, racks and cabling for the required autonomy, plus capacity and impedance testing.

Installation & Commissioning

Input/output cabling, bypass and distribution panels, earthing and full functional testing on site.

Maintenance Contracts

Scheduled preventive maintenance, battery replacement planning and priority breakdown support.

Our Process

From assessment to protected operation

01

Load Survey

We record your critical loads, power quality and required backup time.

02

System Design

UPS rating, topology, redundancy and battery bank are designed and proposed.

03

Supply & Install

Equipment is delivered, installed with proper cabling, protection and earthing.

04

Testing

Load bank, transfer and battery discharge tests confirm performance.

05

Lifecycle Care

Preventive maintenance, monitoring and timely battery replacement.

Deliverables

Protection you can verify

We document every installation so you know exactly how your power protection is designed and how it performs.

  • Load study and UPS sizing report
  • Single-line diagram of the UPS system
  • Battery autonomy calculation
  • Installation and commissioning test report
  • Operation training for your staff
  • Preventive maintenance schedule
Industries We Serve

Who relies on our UPS systems

  • Data Centres
  • Hospitals
  • Banks
  • Telecom
  • Manufacturing
  • Pharmaceutical
  • Educational Institutes
  • Commercial Buildings
FAQ

Frequently Asked Questions

What is the difference between online and line-interactive UPS?

An online double-conversion UPS powers the load continuously from its inverter, so there is no transfer time and the output is fully regulated. It is the recommended choice for servers, medical and industrial control equipment.

How long will the backup last?

Backup time depends on the load and the battery bank. We calculate the battery capacity based on the autonomy you need, whether that is ten minutes to start a generator or several hours of full backup.

How often should UPS batteries be replaced?

VRLA batteries usually last three to five years depending on temperature and cycling. Regular testing lets us replace them based on actual condition rather than guesswork.

Can the UPS work with our generator?

Yes. We check generator sizing and compatibility so the UPS and generator operate together smoothly during changeover.

Related Services

Explore More Solutions

AVR Systems

Automatic Voltage Regulation to keep voltage stable and protect equipment from power fluctuations.

Learn More

Solar Energy Solutions

Efficient solar power that reduces energy costs and provides sustainable generation for industrial applications.

Learn More

Industrial Automation (PLC, HMI & SCADA)

Smart automation using PLC, HMI and SCADA to improve monitoring, control and efficiency of industrial processes.

Learn More

Protect your critical equipment

Tell us your load and backup requirement and we will size the right UPS. Call +92 345 2270942 or email info@dcpspak.com.